Camera System Maintenance

Camera Main Unit Repair:Storz Image1 S/H3, Stryker 1188HD/1288HD, Richard Wolf 5525 HD, Smith & Nephew 560P, Olympus OTV-S7 4K, Storz Image1 4K, Stryker 1588HD, Olympus OTV-S700 3D, Storz Image1 3D, Olympus CV-290, Fujifilm EPX-4400, SonoScape HD-550, etc.

Camera Head Repair:Storz 22220055, Stryker 1488/1588/1688 Compatible Camera Heads, Richard Wolf 8885 Series, Olympus WA50052A, Storz 26605BA, Storz Spies Fluorescence Camera Head, Storz H3-Z/TH100, etc.

Camera System Repair Brands

Imported Flexible Endoscopes:Karl Storz, Olympus, Richard Wolf, Stryker, Smith & Nephew, Arthrex, Aesculap, Xion, ConMed, Joimax, Fujifilm, Pentax;

Domestic Flexible Endoscopes:Domestic Flexible Endoscopes: Mindray, SonoScape, Aohua, Optomic, etc.;

Common Faults of Camera System Repair

  • The main unit fails to detect the camera, with on-screen prompts of no CCD and communication failure error;

    No image output after connecting to the main unit, blank monitor screen;

    Slight shaking of the camera cable causes repeated black screen and intermittent signal loss;

    Overall low image brightness, still dim even with maximum gain;

    Severe color cast on the image, appearing red, green or yellow;

    Horizontal/vertical stripes, screen distortion and heavy snow noise on the image;

    Constant image shaking and flickering with water ripple interference;

    White balance calibration failure, unable to complete calibration;

    No response for snapshot, white balance and zoom buttons on the camera handle;

    Partial handle button failure, spontaneous snapshot triggering;

    Fixed dark spots and shadows in the center or edge of the image blocking the field of view;

    Hazy foggy image, greatly reduced clarity and inability to focus;

    Local color patches, light spots and reflection ghosting on the image;

    Camera overheats after long operation, accompanied by image stuttering and automatic disconnection;

    Water seepage in cable connector, triggering short circuit alarm;

    Cracked or scratched protective lens glass, resulting in blurred and defective imaging;

    Internal fogging inside the camera, blurring the field of view;

    Zoom function failure, unable to zoom in or out;

    Large area color loss in output image, monochrome screen;

    Main unit leakage alarm, slight stinging sensation when touching the camera;

    Deformed pins on camera connector, loose connection and poor contact;

    Main unit parameters reset automatically each time the camera is plugged or unplugged;